Article 192 (Periodical Self-inspections)
  • (1) The employer shall perform self-inspections for a lift for construction work, as to the following matters periodically once every period within one month. However, this shall not apply to the non-use period of the lift for construction work, which is not used for a period of exceeding one month:
    • (i) Abnormalities on brakes and clutches;
    • (ii) Conditions of setting winches;
    • (iii) Damages on wire ropes;
    • (iv) Abnormalities on connecting parts of guy ropes;
    • (v) Damages on wiring, switches and controllers;
    • (vi) Conditions of guide rails.
  • (2) The employer shall, as regards a lift for construction work set forth in the proviso of the preceding paragraph, perform the self-inspection as to the matters listed in each item of the same paragraph, before resuming its use.
Article 193 (Checkup before Commencing Work)
  • (1) The employer shall, when carrying out the work using a lift for construction work, check up as to the following matters before commencing the work for the day.
    • (i) The function of brakes and clutches;
    • (ii) The condition of the parts where wire ropes reeve through.
Article 194 (Checkup after Storm, etc.)
  • (1) The employer shall, when carrying out the work using a lift for construction work (excluding the one installed underground), after the wind having instantaneous wind velocity of exceeding 30 m/s, or after the earthquake of medium intensity or heavier, check up in advance, abnormalities in each part of the lift for construction work.
Article 195 (Record of Self-inspection, etc.)
  • (1) The employer shall record the results of the self-inspections and checkup prescribed in this Section (excluding the checkup set forth in Article 193), and reserve these records for three years.
Article 196 (Repair)
  • (1) The employer shall, when any abnormality is found based on the self-inspection or checkup prescribed in this Section, immediately repair.