Runaway
lift truck hits sweeper. |
A mechanic was
operating a battery-powered lift truck for the test after finishing
repairs on the malfunctioned controller. The truck started to run away all
of sudden and hit a nearby sweeper, causing her an injury of three months.
Wrong wiring he made by mistake was to blame for the accident.
|
|
|
Corrective Action |
1.
|
After repairs
on controllers, be sure to check if the commutation failure protection
circuit functions properly. |
2.
|
When
conducting a test operation, keep a wide area, put up a fence to keep
bystanders off as well as post a work conductor. |
3.
|
Start a test
run at a low speed and bring it up to a high speed, applying load in
several stages. |